PLX32-EIP-MBTCP Communications Gateway Technical Data
PLX32-EIP-MBTCP Communications Gateway Core Technical Data
PLX32-EIP-MBTCP Communications Gateway Power: 24 VDC nominal (10 to 36 VDC), 300 mA.
PLX32-EIP-MBTCP Communications Gateway Temp: -25°C to 70°C (-13°F to 158°F).
PLX32-EIP-MBTCP Communications Gateway Ports: 2 independent RJ45 ports (Must use different subnets).
PROSOFT Communications Gateway Config: Configuration allowed via P1 port only.
PROSOFT Communications Gateway Capacity: 1440 bytes Input / 1440 bytes Output data.
PROSOFT Communications Gateway EIP I/O: Max 8 Class 1 connections (5ms min RPI).
PLX32-EIP-MBTCP PROSOFT Modbus: Max 100 client commands, 10,000 16-bit registers.
PROSOFT Communications Gateway Features And Benefits
Feature: Two physically isolated 10/100 Base-T Ethernet ports.
Benefit: Bridges data across separate subnets without changing IP addresses.
Feature: Embedded Studio 5000 EDS Add-On Profile (AOP).
Benefit: Eliminates custom ladder logic for faster PLC commissioning.
Feature: Concurrent Modbus Client/Server and EtherNet/IP I/O connections.
Benefit: Optimizes bandwidth via independent Requested Packet Interval (RPI) settings.
Feature: Onboard SD card slot for configuration storage.
Benefit: Allows rapid hardware replacement without a configuration PC.
Feature: ProSoft Discovery Service (PDS) network utility.
Benefit: Finds and configures nodes without changing local subnet settings.
If you want to more details about PLX32-EIP-MBTCP PROSOFT,please contact me without hesitate. Email:sales@sparecenter.com
PLX32-EIP-MBTCP PROSOFT FAQ
Q1: Can both Ethernet ports on the PROSOFT PLX32-EIP-MBTCP be on the same subnet?
A: No, the PROSOFT PLX32-EIP-MBTCP requires P1 and P2 to reside on separate subnets to prevent network conflicts.
Q2: Does the PROSOFT PLX32-EIP-MBTCP require custom PLC ladder logic?
A: No, the PROSOFT PLX32-EIP-MBTCP uses an embedded Studio 5000 AOP to map data automatically as native I/O tags.
Q3: What is the cyclic data limit for the PROSOFT PLX32-EIP-MBTCP?
A: The PLX32-EIP-MBTCP PROSOFT supports a maximum of 1440 bytes of Input and 1440 bytes of Output data per cycle.
Q4: How do you restore a backup on the PROSOFT PLX32-EIP-MBTCP without a PC?
A: Insert the configuration SD card directly into the new PLX32-EIP-MBTCP PROSOFT unit for instant hardware replacement.
Other Module
| SE4036P2 KJ3241X1-BK1 12P4710X042 | KJ3241X1-BA1 12P2506X042 |
| WH5D-2FF 1X00416H03 | KJ4001X1-CA1 12P0623X062 |
| 1B30035H01 | KJ3002X1-BG2 12P1731X082 |
| CON041 PR6423/000-131 | KJ3221X1-BA1 12P2531X082 VE4003S2B2 |
| CON041 PR6424/000-121 | MMS6110 |
| 1X01046H01L | KJ2201X1-HA1 12P3322X022 |
| PR6423/015-111 CON041 | PR6423/002-030 CON021 |
| KJ4001X1-NB1 12P3368X012 | PR6423/00R-010 CON021 |
| PR6423/010-000 CON021 | KJ3221X1-BA1 12P2531X102 |
| A6312/08 | KJ3222X1-BA1 12P2532X072 |
| PR6423/000-010 CON021 | KJ2003X1-BB1 12P3439X012 |
| PR9268/200-000 | KJ3241X1-BA1 12P2506X042 VE4006P2 |
| PR6424/000-030 CON021 | KJ4001X1-BE1 12P0818X072 |
| PR6423/00R-101 CON031 | PR6423/010-010 CON021 |
| KJ3222X1-BA1 12P2532X122 VE4033S2B1 | PR6423/013-020 CON021 |
Contact Us
Email: sales@sparecenter.com