Specifications Sheet Of EPRO CON041
Dynamic Performance | ||
Frequency Range (-3 dB) | 0 to 20,000 Hz | ![]() |
Rise Time | <15µs | |
NOTE: Designed for PR6422, PR6423, PR6424, PR6425, PR6426 For Extended Range Use: CON041/91x-xxx PR6425 Requires Extended Range Converter | ||
Environmental | ||
Operating Temperature Range | -30 to 100°C (-22 to 212°F) | |
Shock and Vibration | 5g @ 60Hz @ 25°C (77°F) | |
Protection Class | IP20 | |
Power & Electrical | ||
Supply Voltage Range | -23V to -32V (Output Range -4V to -20V) | |
-21V to -32V (Output Range -2V to -18V) | ||
Physical | ||
Housing Material / Weight | PA 6.6 / ~60 grams (2.12 oz) | |
Mounting | Din Rail | |
Connections | Screw Terminal (Max. 1.5mm2, Wire-end Sleeves) |
Specifications Sheet Of PR6424/104-141
Dynamic Performance | |
Sensitivity/Linearity | 4 V/mm (101.6 mV/mil) ≤ ±1.5% |
Air Gap (Center) | Approx. 2.7 mm (0.11”) Nominal |
Long Term Drift | < 0.3% |
Range Static | ±2.0 mm (0.079”) |
Target | |
Target/Surface Material | Ferromagnetic Steel (42 Cr Mo4 Standard) |
Maximum Surface Speed | 2,500 m/s (98,425 ips) |
Environmental | |
Operating Temperature Range | -35 to 150°C (-31 to 302°F) |
Temperature Error | <4%/100°K (API 670 Compliant) |
Pressure Resistance to Sensor Head | 10,000 hPa (145 psi) |
Shock and Vibration | 5g @ 60Hz @ 25°C (77°F) |
If you want to more details,please contact me without hesitate.Email:sales@sparecenter.com
FAQs of EPRO PR6424/104-141 CON041
What is the PR6424/104-141 sensor used for?
This sensor is used for non-contact displacement and vibration measurement, ideal for machinery condition monitoring in industrial applications.
How does the sensor work?
It uses eddy current technology to detect changes in displacement or vibration without physical contact, offering high accuracy and durability.
What industries is this sensor suitable for?
The sensor is widely used in industries such as power generation, oil and gas, manufacturing, and other heavy industries for condition monitoring and diagnostics.
Other Modules
EMERSON | PR6424/010-010 | Eddy Current Sensor |
EMERSON | KJ4001X1-CA1 12P0623X072 | I/O Terminal Block |
EMERSON | KJ2002X1-BA1 12P1442X062 VE3002 | DeltaV Controller |
EMERSON | KJ3002X1-BG2 12P1731X022 VE4003S5B1 | DeltaV Thermocouple mV card |
EMERSON | PR6423/009-031 CON041 | Eddy Current Signal Converter |
EMERSON | PR6426/010-000 CON021/916-160 | Eddy Current Sensor |
EMERSON | PR6423/10R-040 CON021 | Eddy Current Sensor |
EMERSON | PR9268/302-000 | Eddy Current Sensor |
EMERSON | EMERSON PR6424/104-141 EMERSON PR6424/104-141 | EMERSON PR6424/104-141 EMERSON PR6424/104-141 |
EMERSON | EMERSON CON041 EMERSON CON041 | EMERSON CON041 EMERSON CON041 EMERSON CON041 |
EMERSON | EMERSON Eddy Current Sensor EMERSON Eddy Current Sensor | EMERSON Eddy Current Sensor EMERSON Eddy Current Sensor |
EMERSON | EMERSON CON041 EMERSON CON041 | EMERSON CON041 EMERSON CON041 |
EMERSON | CON041 CON041 CON041 | EMERSON PR6424/104-141 |
Mobile/what's app: +852 6980 6006
Email: sales@sparecenter.com