Product Datasheet
Manufacturer: | Bently Nevada |
Model Number: | 330102-00-40-10-02-00 |
Type: | Proximity Probe |
Measurement Range: | ±0.030 inches (±0.762 mm) |
Operating Temperature Range: | -40°C to +85°C (-40°F to +185°F) |
Mounting Type: | Typically mounted on a bearing housing or machine frame |
Output Signal: | 4-20 mA, proportional to displacement |
Frequency Response: | Up to 100 kHz |
Cable Length: | 10 feet (3 meters) standard; custom lengths available |
Weight: | Approximately 0.3 kg (0.66 lbs) |
3300XL 8mm Proximity Transducer System Datasheet
Performance over Extended Temperatures | |
Standard 5 or 1
meter System | Over a probe temperature range of –35°C to +120°C (-31°F to +248°F) with the Proximitor sensor and extension cable between0°C to +45°C (+32°F to +113°F), the ISF remains within ±10% of 7.87 V/mm (200 mV/mil) and the DSL remains within ±0.076 mm (±3 mils). Over a Proximitor sensor
and extension cable
temperature range of –
35°C to +65°C (-31°F to
+149°F) with the probe
between 0°C to +45°C
(+32°F to +113°F), the ISF
remains within ±10% of 7.87
V/mm (200 mV/mil) and
the DSL remains within
±0.076 mm (±3 mils). |
Standard 9
meter System | Over a probe temperature range of –35°C to +120°C (-31°F to +248°F) with the Proximitor sensor and extension cable between0°C to +45°C (+32°F to +113°F), the ISF remains within ±18% of 7.87 V/mm (200 mV/mil) and the DSL remains within ±0.152 mm (±6 mils). Over a Proximitor sensor and extension cable temperature range of – 35°C to +65°C (-31°F to +149°F) with the probe between 0°C to +45°C (+32°F to +113°F), the ISF remains within ±18% of 7.87 V/mm (200 mV/mil) and the DSL remains within±0.152 mm (±6 mils). |
Extended
Temperature
Range 5 and 9
meter Systems | Over a probe and
extension cable
temperature range of –
35°C to +260°C (-31°F to
+500°F) with the Proximitor
sensor between 0°C to
+45°C (+32°F to +113°F), the
ISF remains within ±18% of
7.87 V/mm (200 mV/mil)and the DSL remains within±0.152 mm (±6 mils). |
Frequency
Response | (0 to 10 kHz), +0, -3 dB, with
up to 305 meters (1000
feet) of field wiring. |
Minimum Target
Size | 15.2 mm (0.6 in) diameter
(flat target) |
Shaft Diameter | |
Minimum | 50.8 mm (2 in) |
Recommended
Minimum | 76.2 mm (3 in) |
![]() |
Other Modules
BENTLY NEVADA 330102-00-40-10-02-00 BENTLY NEVADA 330102-00-40-10-02-00-CN BENTLY NEVADA 330102-00-40-10-02-00 BENTLY NEVADA 330102-00-40-10-02-00-CN Bently Nevada Cable PLC Module Bently Nevada 3300 XL Bently Nevada Cable PLC Module Bently Nevada 3300 XL Bently Nevada Cable PLC Module Bently Nevada 3300 XL BENTLY NEVADA 330102-00-40-10-02-00 BENTLY NEVADA 330102-00-40-10-02-00-CN BENTLY NEVADA 330102-00-40-10-02-00 BENTLY NEVADA 330102-00-40-10-02-00-CN Bently Nevada Proximity Probe Bently Nevada Proximity Probe Bently Nevada 3300 XL Bently Nevada 3300 XL Bently Nevada 3300 XL Bently Nevada Proximity Probe Bently Nevada Proximity Probe Bently Nevada Proximity Probe Bently Nevada Proximity Probe |
Mobile/what's app: +852 6980 6006