1
Product Specification
Dynamic signal inputs | Image | |
Number of inputs | 4 per MPC4 card | ![]() |
DC range | 0 to +20 V or 0 to −20 V | |
AC range | ±10 V max. | |
Common mode voltage range | −50 to +50 V | |
CMRR | >60 dB at 50 Hz | |
Crosstalk | −72 dB | |
Input impedance | 200 kΩ | |
Current input range | ||
• DC signals | 0 to 25 mA | ![]() |
• AC signals | ±8 mA max. | |
Analog frequency range | DC to 60 kHz (−3 dB). Note: Applicable when dynamic signal outputs are shared using the Raw bus (VM600 rack). Dynamic signal outputs can be shared with XMx16/XIO16T card pairs but cannot be shared with other MPC4/IOC4T card pairs. | |
Analog AC frequency range | ||
• Without integration | 0.1 Hz to 10 kHz | |
• With integration | 2.5 Hz to 10 kHz | |
Current measuring resistor | 324.5 Ω |
2
KEY FEATURES AND BENEFITS
1
♦ From the Vibro-Meter® product line
♦ Continuously online machinery protection card
♦ Real-time measurement and monitoring using state-of-the-art DSP techniques
♦ 4 dynamic signal channels and 2 tachometer (speed) channels, all individually programmable
2
♦ Programmable broad-band and narrow-band filters
♦ Simultaneous amplitude and phase monitoring in order-tracking mode
♦ Programmable Alert, Danger and OK set points
♦ Adaptive Alert and Danger levels
3
♦ Front-panel BNC connectors for easy analysis of buffered “raw” sensor signals
♦ Front-panel LEDs indicate status and alarms
♦ Integrated power supplies for sensors and signal conditioners such as IEPE accelerometers and proximity measurement systems
If you want to more details,please contact me without hesitate.Email:sales@sparecenter.com
3
Buffered dynamic signal outputs
The buffered “raw” dynamic signal outputs are available on the front-panel BNC connectors (MPC4 card) and the screw-terminal connectors (IOC4T card). | |
Output impedance | 50 Ω |
Analog frequency range | DC to 10 kHz (−0.1 dB with a load >1 MΩ). DC to 10 kHz (−0.2 dB with a load >200 kΩ). DC to 40 kHz (−3 dB). Note: Applicable when buffered “raw” dynamic signal outputs are shared using the front-panel BNC connectors (VM600 MPC4 card) and the screw-terminal connectors (VM600 IOC4T card). |
Phase error | <5° (DC to 1 kHz). <30° (DC to 10 kHz). |
Transfer ratio | |
• Voltage input | 1 V/V |
• Current input | 0.3245 V/mA |
4
Other Modules
ABB | 3BHE014967R0001 UNS2880B-P | MPC4 MPC4 MPC4 MPC4 MPC4 MPC4 MPC4 MPC4 |
ABB | HIEE305106R0001 UNS0017A-P | UNITROL 5000 Firing unit |
ABB | HIEE405246R0002 UNS0867A-P | Extension Card I/O |
ABB | HIEE400961R0001 UFB009AE01 | Precision Regulator |
ABB | MPC4 MPC4 MPC4 MPC4 MPC4 | Analog Output Module |
ABB | SPICT13A MPC4 MPC4 | Vibro-Meter VM600 Vibro-Meter VM600 Vibro-Meter VM600 Vibro-Meter VM600 |
ABB | 3Vibro-Meter VM600 Vibro-Meter VM600 Vibro-Meter VM600 Vibro-Meter VM600 | Vibro-Meter VM600 Vibro-Meter VM600 Vibro-Meter VM600 Vibro-Meter VM600 |
ABB | 086384-003 | Control Board |
ABB | 086387-001 | MPC4 VM600 MPC4 VM600 MPC4 VM600 |
ABB | SDCS-REB-1C | Vibro-Meter VM600 Vibro-Meter VM600 |
Vibro-Meter VM600 | Vibro-Meter VM600 | Vibro-Meter VM600 Vibro-Meter VM600 |
SOLENOID JUMPER | SOLENOID JUMPER H6142-05 | SOLENOID JUMPER H6142-05 SOLENOID JUMPER H6142-05 |
Vibro-Meter VM600 | SOLENOID JUMPER PC Board | SOLENOID JUMPER PC Board SOLENOID JUMPER PC Board |
Vibro-Meter VM600 | Vibro-Meter VM600 | MPC4 VM600 MPC4 VM600 MPC4 VM600 |
Vibro-Meter machinery protection card | Vibro-Meter machinery protection card Vibro-Meter machinery protection card | Vibro-Meter machinery protection card Vibro-Meter machinery protection card |
Vibro-Meter machinery protection card Vibro-Meter machinery protection card | MPC4 VM600 MPC4 VM600 | Vibro-Meter MPC4 Vibro-Meter MPC4 Vibro-Meter MPC4 |
SOLENOID JUMPER | SOLENOID JUMPER Module | Vibro-Meter MPC4 Vibro-Meter MPC4 Vibro-Meter MPC4 |
Vibro-Meter MPC4 | Vibro-Meter MPC4 Vibro-Meter MPC4 | Vibro-Meter MPC4 Vibro-Meter MPC4 Vibro-Meter MPC4 |
Mobile/what's app: +852 6980 6006
Email: sales@sparecenter.com