• MRI-234 B YOKOGAWA Automation Module
  • MRI-234 B YOKOGAWA Automation Module
  • MRI-234 B YOKOGAWA Automation Module
  • MRI-234 B YOKOGAWA Automation Module
  • video

MRI-234 B YOKOGAWA Automation Module

  • YOKOGAWA
  • Japan
  • 2024
  • In Stock
The YOKOGAWA MRI-234 B is a Power Supply Module designed to provide stable power within Yokogawa automation modules.This regulated 5 VDC output is then used to supply power to the onboard logic circuits of various Yokogawa control system components, ensuring their reliable operation.

Product Specifications


ItemSpecification
Manufacturers :YOKOGAWA 
Part No.:MRI-234 B 
Product Type: Automation Module
Dimensions:2.5 cmx 22.9 cmx 7.6 cm
Weight:0.1kg
Temperature(Normal operation)0 to 50 °C 
Humidity (Normal operation)10 to 90 %RH  (In case of FIO / 5 to 95 %RH) 
Voltage range100-120 V AC ±10 % 220-240 V AC ±10 % 24 V DC ±10 % 
Frequency 50/60 ±3 Hz 
Distortion factor10 % or less 
10 % or less 125 V or larger (for 100-120 V AC) 274 V or larger  (for 220-240 V AC) 
Insulation resistance 20 Mohms at 500 V DC 


YOKOGAWA MRI-234 B Details


Details

Control Room Environment:This section describes environmental conditions of the control room to operate the system safely, and stably over a long period of time. It is recommended that user have the control room environment assessment. Consult Yokogawa sales for the assessment if necessary. n Temperatures and Humidity When equipment is brought from the place out of operational temperature range to the place in operational temperature range, bring it without a package, keep it within temperature change rate and avoid condensation.  Keep ambient temperature within operational temperature range and leave it for more than three hours before starting operation. Under normal operation, the rate of change of ambient temperatures should be within 10 °C/h. All the equipment should be kept out of direct sunlight.

Power Supply System:Voltage and frequency fluctuations are within the limits specified for each ystem component. •Relationship betweenthe waveform’s effective values and peak value is within the specified range.

AC Power Specification :AC power used for the system must satisfied rated voltage and the peak value must be greater than the minimum specified (see below). DC power must satisfied 24 V DC at the power supply terminals.

Selecting a Power System: The CENTUM VP system requires a power supply that satisfies power requirements in accordance with EMC regulations. It is recommended that an external power supply unit is employed in order to prevent disruptions due to momentary or extended power failure, line noise, or lightening surges, as well as to suppress harmonic current from various devices. For selection of the power supply unit, consult with a power unit manufacturer taking the following points into consideration. 

If you want to more details,please contact me without hesitate.Email:sales@sparecenter.com


  YOKOGAWA MRI-234 B Overview


Overview

The output board UTK-2 is used for controlling external relays, e.g. for fans and fire doors. The UTK-2 board is controlled by the alarm processor board LPK-2, via the address and data buses in the back plane. The UTK-2 board is equipped with 24 opto-isolated outputs for 24 VDC/50 mA. The outputs are divided into six groups where each group includes four outputs and a common positive conductor.  

The DC/DC circuit converts the battery voltage of the back plane to 5 VDC, which is supplied to all logical circuits on the board. Should the voltage disappear, a signal is activated in the back-plane. 

The battery voltage is fused. If the fuse is blown a signal is activated in the back-plane. The fuse is accessible on the front panel of the board, and can be used for disconnecting the power. 

On the front panel are two green LEDs for indicating 5V power and normal polling. 

The address bus, the data bus and the control signals are buffered before entering the board. 

The value written to the outputs can be read, to check the function of the board.  

The output latches also functions as drive circuits for the opto switches. 

s The outputs are divided into six groups, where each group has a common positive conductor. The load is connected between the output and ground. Each output is protected by a varistor and a freewheel diode for inductive loads. 



Other Modules


ABBSNAT6030BEB SNAT 6030 BEBStromberg Drives
ABBHESG330086R64 HE693116-307Control Board
ABBSAFT181INF SAFT 181 INFInterface Board
ABBSAFT103CON 57777290 SAFT 400F380E 57778865CPU Control PCB Circuit Board
MRI-234 B YOKOGAWA Automation ModuleSAFT171PAC  SAFT 171 PACPulse Amplifier Card
MRI-234 B YOKOGAWA Automation ModuleSAFT103CONB SAFT315F380CPU Control PCB Circuit Board
MRI-234 B YOKOGAWA Automation ModuleYOKOGAWA MRI-234 B YOKOGAWA MRI-234 B 
YOKOGAWA MRI-234 B YOKOGAWA MRI-234 B Brake Release Board
YOKOGAWA MRI-234 B MRI-234 B Automation ModuleMRI-234 B Automation Module
YOKOGAWA MRI-234 B MRI-234 B Automation ModuleMRI-234 B Automation Module
MRI-234 B Automation ModuleMRI-234 B Automation ModuleMRI-234 B YOKOGAWA Automation Module
MRI-234 B Automation ModuleMRI-234 B YOKOGAWA Automation ModuleMRI-234 B YOKOGAWA Automation Module
MRI-234 B Automation ModuleMRI-234 B YOKOGAWA Automation ModuleABB Control Board ABB Control Board ABB Control Board

MRI-234 B

Mobile/what's app: +852 6980 6006

Email: sales@sparecenter.com

CUSTOMER VOICE

Get the latest price? We will reply as soon as possible (within 12 hours)

Sparecenter sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Sparecenter is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
("[type='submit']")