KEBA DO 272A 070290 KEMRO K2-200 Specifications
Model | DO 272/A |
Power supply voltage: | 24 V DC from the front (19.2 V to 30 V, acc. to IEC61131-2) 24 V DC from K Bus 5 V DC from K Bus |
Overvoltage category: | II |
Equipment class: | III according to EN 61131-2:2007 |
Addressing at K-Bus: | Via 16-digit address switch, on the side |
Connection terminals: | Open terminals, grid dimensions 5.08 mm |
Max. power consumption K Bus 24 V: | 2.1 W |
Max. power consumption K Bus 5 V: | 0.4 W |
Environmental conditions | |
Operating temperature: | +5 °C to +55 °C |
Storage temperature: | -40 °C to 70 °C |
Relative humidity of air: | 10 % to 95 % (non condensing) |
Vibration resistance: | according to EN 61131-2:2007 |
Shock resistance: | according to EN 61131-2:2007 |
Details of KEBA DO 272A 070290 KEMRO K2-200
1
Intended use
The DO 272/A was developed for control applications in industrial machines. The typical applications areas include injection molding machines, robots, presses, machine tools and similar.
The DO 272/A may only be used for the types of use described in the technical descriptions and only in conjunction with recommended/approved third-party equipment/installations.
2
Configuration
A Kemro system needs data for the configuration of system performance, its I/O-devices and interfaces. The system reads this data during the start-up operation and allocates them to its components and devices. Configuration data is created by included configuration tools or by editing configuration files. For further information to the configuration see the documentation of the included configuration tool.
3
Feature
14 Digital Outputs: Capable of controlling multiple devices simultaneously.
2A Nominal Current: Each output can handle up to 2A, suitable for various applications.
24V DC Supply Voltage: Designed for use with a standard 24V DC power supply.
Isolated Outputs: Provides electrical isolation between outputs and the control logic for safety and reliability.
If you want to more details,please contact me without hesitate.Email:sales@sparecenter.com
More Technical Data And Image
Technical Data | Image | |
Number of outputs: | 14 | ![]() |
Rated voltage: | 24 V DC | |
Processing time: | 1 ms | |
Rated current: | 1 ms | |
Rated current: | 2 A at 50 % coincidence per group | |
Galvanic isolation: | Yes, to selection electronics and among themselves Electric strength: 707 V with unsewed ground connection | |
Status display: | Orange LED | |
Max. inductive load: | 1 J at max. 0.2 Hz | |
System bus interface: | Parallel bus interfaces, plug-in on side | |
Module height: | 120 mm | |
Mounting depth: | 100 mm | |
Protection device: | Short circuit protection |
Other Module
EMERSONPR6426/000-131 CON041Eddy Current Sensor EMERSON1X00691H01Ovation PMOD Cavity Plastic Insert EMERSON1X00884H01Compact Controller EMERSON775XD11NAWA3WK9Wireless Adapter EMERSONW74C5X1Signal Transfer Board EMERSONMMS6110Relative rotor vibration monitor EMERSONKJ3222X1-BA1 12P2532X072 VE4033S2B1Analog Input EMERSONKC3010X1-BA1 12P6762X062Traditional I/O EMERSONKJ1501X1-BC1 12P2186X032 VE5008Power Supply EMERSONKJ3221X1-BA1 12P2531X102 VE4035S2B1Electronic Unit Controller KEBA DO 272A 070290 KEBA DO 272A 070290 KEBA DO 272A 070290 KEBA PLC Digital Outpu Module KEBA PLC Digital Outpu Module KEBA PLC Digital Outpu Module KEBA PLC Digital Outpu Module K2-200 K2-200 K2-200 KEBA DO 272A 070290 KEBA DO 272A 070290 DO 272A 070290 DO 272A 070290 DO 272A 070290 K2-200 K2-200 K2-200 K2-200 K2-200 KEMRO K2-200 KEMRO K2-200 KEMRO K2-200 KEMRO K2-200 KEMRO K2-200 KEMRO K2-200 KEMRO KEMRO K2-200 KEMRO K2-200 KEMRO K2-200 KEMRO K2-200 KEMRO K2-200 |
Mobile/what's app: +852 6980 6006