Product Specification
Specifications | |
Unless otherwise noted, the following
specifications are for a 3300 XL 8 mm
Proximitor Sensor, extension cable and 8 mm
probe between +18˚C and +27˚C (+64˚F to
+80˚F) at a maximum altitude of 2000 meters,
with a -24 Vdc power supply, a 10 kΩ load, an
AISI 4140 steel target, and a probe gapped at1.27 mm (50 mils). Performance characteristics
apply to systems that consist solely of 3300 XL 8
mm components. The system accuracy and
interchangeability specifications do not apply
to transducer systems that are calibrated to
any target other than our AISI 4140 steel target. | |
Electrical | |
Proximitor
Sensor Input | Accepts one non-contacting
3300-series 5 mm, 3300 XL 8
mm Proximity Probe and
Extension Cable. |
Power | Requires -17.5 Vdc to -26 Vdcwhen installed with non-incendive circuit connected
per installation drawing 140979
at 12 mA maximum
consumption, -23 Vdc to -26
Vdc with barriers. Operation at
a more positive voltage than-23.5 Vdc can result in reduced
linear range. |
Supply
Sensitivity | Less than 2 mV change in
output voltage per volt change
in input voltage. |
Output
Resistance | 50 Ω |
Nominal Probe DC Resistance | |
Resistance (RPROBE) from Center Conductor
to Outer Conductor | |
Probe
Length (m) | RPROBE(Ω) |
0.5 | 7.45 ± 0.50 |
1.0 | 7.59 ± 0.50 |
1.5 | 7.73 ± 0.50 |
2.0 | 7.88 ± 0.50 |
3.0 | 8.17 ± 0.50 |
5.0 | 8.73 ± 0.50 |
9.0 | 9.87 ± 0.50 |
If you want to more details,please contact me without hesitate.Email:sales@sparecenter.com
Product Datasheet
Extension Cable
Capacitance | 69.9 pF/m (21.3 pF/ft)
typical |
Field Wiring | 0.2 to 1.5 mm2 (16 to 24
AWG). Recommend using
3 conductor shielded triad
cable and tinned field
wiring. Maximum length of
305 meters (1,000 feet)
between the 3300 XL
Proximitor Sensor and the
monitor. See the frequency
response graphs, Figures
10 and 12, for signal rolloff
at high frequencies when
using longer field wiring
lengths. |
Linear Range | 2 mm (80 mils). Linear
range begins at
approximately 0.25 mm (10
mils) from target and is
from 0.25 to 2.3 mm (10 to
90 mils) (approximately –1
to –17 Vdc). |
Recommended
Gap Setting for
Radial Vibration | -9 Vdc [approximately 1.27
mm (50 mils)] |
Incremental Scale Factor (ISF) | |
Standard 5 or 1
meter System | 7.87 V/mm (200 mV/mil) ±
5% including
interchangeability error
when measured in
increments of 0.25 mm (10
mils) over the 80 mil linear
range from 0°C to +45°C
(+32°F to +113°F). |
Standard 9
meter System | 7.87 V/mm (200 mV/mil)
± 6.5% including
interchangeability error
when measured in
increments of 0.25 mm (10
mils) over the 80 mil linear
range from 0°C to +45°C
(+32°F to +113°F). |
Extended
Temperature
Range (ETR) for 5
and 9 Meter
Systems | 7.87 V/mm (200 mV/mil) ±
6.5% including
interchangeability error
when measured in
increments of 0.25 mm (10
mils) over the 80 mil linear
range from 0°C to +45°C
(+32°F to +113°F). |
Deviation from best fit straight line (DSL) | |
Standard 5 or 1
meter System | Less than ±0.025 mm (±1
mil) with components at
0°C to +45°C (+32°F to
+113°F). |
Standard 9
meter System | Less than ±0.038 mm (±1.5
mil) with components at
0°C to +45°C (+32°F to
+113°F). |
Extended
Temperature
Range 5 and 9
meter Systems | Less than ±0.038 mm (±1.5
mil) with components at
0°C to +45°C (+32°F to
+113°F). |
Other Modules
Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System Bently Nevada 3300 XL 330104-00-15-10-01-CN Proximity Transducer System BENTLY NEVADA 330104-00-15-10-01-CN BENTLY NEVADA Proximity Transducer System BENTLY NEVADA 330104-00-15-10-01-CN BENTLY NEVADA Proximity Transducer System BENTLY NEVADA 330104-00-15-10-01-CN BENTLY NEVADA Proximity Transducer System BENTLY NEVADA 330104-00-15-10-01-CN BENTLY NEVADA Proximity Transducer System BENTLY NEVADA 330104-00-15-10-01-CN BENTLY NEVADA Proximity Transducer System BENTLY NEVADA 330104-00-15-10-01-CN BENTLY NEVADA Proximity Transducer System BENTLY NEVADA 330104-00-15-10-01-CN BENTLY NEVADA Proximity Transducer System BENTLY NEVADA 330104-00-15-10-01-CN BENTLY NEVADA Proximity Transducer System |