505-4916A relay output module Details
Channels: 16 output points, Form A configuration (Normally Open)
Isolation: 4 isolated groups (4 channels per shared common)
AC Voltage: 20 to 265 VAC (50/60 Hz)
DC Voltage: 4.5 to 30 VDC
Current Capacity (Resistive): 2.0A maximum per point
Current Capacity (Inductive AC): 1.0A maximum per point
Current Capacity (Inductive DC): 0.88A maximum per point
Status Indication: 16 front-panel diagnostic LEDs mapping physical logic states
If you want to more details about Siemens relay output module,please contact me without hesitate.Email:sales@sparecenter.com
505-4916A relay output module Key Function
Digital-to-Relay Signal Conversion: Converts low-voltage internal PLC backplane logic signals into robust mechanical relay switching actions via the 505-4916A relay output module's 16 output channels.
Heavy-Duty Load Switching: Enables the 505-4916A Siemens to directly drive external industrial field devices including solenoids, motor starters, contactors, and pilot lamps.
Isolated Circuit Protection: Utilizes the 505-4916A Siemens's group-to-group electrical isolation to safeguard internal PLC backplane electronics from field-side electrical noise and transient voltage spikes.
Universal Voltage Interfacing: Supports flexible voltage routing across a wide operating range, allowing the 505-4916A relay output module to manage both AC loads and DC loads on a single module.
Real-Time Visual Diagnostics: Provides instant loop-status verification via the 16 front-panel LED indicators on the Siemens 505-4916A, reflecting the physical on/off state of each output channel.
Reasons For Choosing Spare Center
Massive Stock
Over 1M products ready for same-day shipping.
Global Support
Multilingual team serving 100+ countries.
Guaranteed Quality
Original origin testing with third-party verification.
Flexible Shipping
Global delivery via DHL, FedEx, TNT, and UPS.
505-4916A Siemens FAQ
Q: In which specific control architectures can the Siemens 505-4916A module be deployed?
A: The 505-4916A Siemens is engineered exclusively for the legacy Texas Instruments (TI) Series 505 and SIMATIC TI 505 PLC slots, running under standard backplane rack addressing.
Q: Does the Siemens 505-4916A provide individual fuse protection for each of its output channels?
A: No, unlike other modules in the same series, the 505-4916A Siemens is not fuse-protected on its circuitry, requiring engineers to install external inline fuses to prevent field short-circuits.
Q: Are the contacts of an unpowered or faulted Siemens 505-4916A module open or closed?
A: The 505-4916A Siemens utilizes a Form A relay configuration, meaning all 16 channels are inherently Normally Open (NO) and will immediately open if the PLC loses power or fails.
Q: Can the Siemens 505-4916A handle high-frequency switching or high-speed pulse-width modulation (PWM)?
A: No, due to the physical latency and finite cycle life of its electromechanical relays, the 505-4916A Siemens is restricted to low-frequency on/off operations and cannot be used for rapid pulse control.
Q: What is the current manufacturing lifecycle status of the Siemens 505-4916A?
A: The 505-4916A Siemens is officially discontinued; facility maintenance managers must now rely on certified refurbished stock, surplus units, or drop-in alternatives like the CTI 2532.
Other Modules
| 6ES7322-1BL00-0AA0 | 6ES7951-0KF00-0AA0 |
| 6ES7392-1AM00-0AA0 | 6AV3503-1DB10 |
| 6ES7153-2BA02-0XB0 | 6ES7421-1BL01-0AA0 |
| 6ES7321-1BH02-0AA0 | 6ES7511-1AK01-0AB0 |
| 6ES7531-7KF00-0AB0 | 6ES5948-3UR23 |
| 6EP1334-3BA10 | 500-033260 |
| 6EP1336-3BA00 | 6ES7221-1BH32-0XB0 |
| 6ES7392-1AJ00-0AA0 | 6ES7131-4BD01-0AA0 |
| 6ES7214-1AG40-0XB0 | 6ES7532-5HF00-0AB0 |
| 6ES7422-1BL00-0AA0 | 6AV6643-0DD01-1AX1 |
| 6ES7332-5HF00-0AB0 | 6ES7222-1BH32-0XB0 |
| 6SE7033-5GJ84-1JC0 | 6ES5465-4UA12 |
| 6ES7331-7KF02-0AB0 | 6AV6647-0AK11-3AX0 |
| 6AV2124-0MC01-0AX0 | 6ES7412-2XG00-0AB0 |
| 6AV3627-1LK00-1AX0 | 6ES7522-1BH00-0AB0 |

Email: sales@sparecenter.com