BERGER LAHR stepper drive Data
Type: TLD012 F (Twin Line stepper/servo drive)
BERGER LAHR TLD012F Material No.: 0063401200001
BERGER LAHR TLD012F Serial No.: 1310027386
BERGER LAHR TLD012F Program No. (Firmware): 730.00 Rev. 1.010
Mains (Input): 230 VAC (Max voltage to ground < 300 VAC)
TLD012F stepper drive Modules Slot: PULSE
Hardware Rev.: RS 22
Certifications: CE / cULus Listed (91ZA IND. CONT. EQ.)
If you want to more details about BERGER LAHR stepper drive,please contact me without hesitation.Email:sales@sparecenter.com
BERGER LAHR stepper drive Images
BERGER LAHR stepper drive (BERGER LAHR TLD012F)
TLD012F (BERGER LAHR TLD012F)
TLD012F (BERGER LAHR TLD012F)
The Spare Center Advantage: Fast, Global, Reliable.
Rapid Delivery
Housing Asia’s largest PLC warehouse with over 1 million products, we guarantee same-day shipping and rush processing to eliminate downtime.
Global Brands & Obsolete Parts
We supply major brands like Bently Nevada, GE, ABB, Honeywell, and Emerson, specializing in sourcing rare and obsolete components.
Certified Quality & Logistics
All items pass original tests and support third-party verification. We partner with DHL, FedEx, TNT, and UPS to serve over 100 countries.
TLD012F BERGER LAHR Faults & Troubleshooting
1. TLD012F BERGER LAHR Overcurrent / Short Circuit
Causes: Motor short circuit, internal IGBT failure, or mechanical jam.
Actions: Disconnect power, wait 6 minutes, unplug motor, and power on. If error persists, drive is damaged. Check mechanical binding.
2. TLD012F BERGER LAHR Overvoltage / Undervoltage
Causes: Unstable grid input or fast deceleration causing energy backfeed.
Actions: Verify stable 230 VAC at Mains terminals. Increase deceleration ramp time in PLC software.
3. TLD012F BERGER LAHR PULSE / Comm Error
Causes: Loose PULSE module connector, no PLC pulse, or signal noise.
Actions: Tighten PULSE module terminal block. Use shielded twisted-pair cables and ground chassis.
4. TLD012F BERGER LAHR Drag Error / Overheat
Causes: Position deviation exceeded limit or motor overloaded.
Actions: Check motor temperature, reduce load, and check encoder feedback cable for damage.
TLD012F FAQ
Q1: What are the main applications of the TLD012F BERGER LAHR?
A1: The TLD012F stepper drive is primarily used in industrial automation for precise positioning control, commonly driving 5-phase stepper motors in CNC machines, packaging lines, and multi-axis alignment systems.
Q2: Why does the TLD012F stepper drive show an overcurrent error during startup?
A2: An overcurrent error on the TLD012F stepper drive is usually caused by a short circuit in the motor winding, damaged power cables, a mechanical axis jam, or an internal breakdown of the drive's IGBT power module.
Q3: How to troubleshoot a "PULSE" communication fault on the TLD012F BERGER LAHR?
A3: First, verify that the PLC pulse signal is actively sending commands to the TLD012F stepper drive. Then, tighten the PULSE module terminal connectors and ensure shielded twisted-pair wiring is used to block electromagnetic interference.
Q4: Is the TLD012F BERGER LAHR still in active production by Schneider Electric?
A4: No, the TLD012F stepper drive is a legacy product and has been officially discontinued, but you can purchase the original unit or compatible replacements directly from our spare center.
Other Modules
| TK-IOLI01 51403427-275 | FC-TSAI-1620M |
| 51202324-100 | MC-TAIH12 51304337-150 |
| 51202324-300 | 80363975-100 |
| 51202329-102 | MC-TDIA12 51304439-175 |
| 51202329-112 | TC-PRR021 51309288-225 |
| 51202329-202 | FC-TSDI-16UNI |
| 51202329-212 | 51305776-100 51305759-100 |
| 51202329-402 | 51305508-200 |
| 51202329-602 | CC-PDIS01 51405042-175 |
| 51202329-616 | FC-TSHART-1620M |
| 51202329-732 | 51303979-550 |
| 51202343-001 | 51304518-150 |
| 51304465-500 | 51402615-400 |
| 51305381-500 | 51305072-600 |
| LCNP4E 51405098-100 | TC-FXX072 |
| MC-PLAM02 51304362-150 | 51201557-150 |
| 10100/2/1 | MC-PAIH03 51304754-150 |