• Allen Bradley 1747-ACN15-A ControlNet Adapter Module
  • Allen Bradley 1747-ACN15-A ControlNet Adapter Module
  • Allen Bradley 1747-ACN15-A ControlNet Adapter Module
  • Allen Bradley 1747-ACN15-A ControlNet Adapter Module
  • video

Allen Bradley 1747-ACN15-A ControlNet Adapter Module

  • Allen Bradley
  • USA
  • 2024
  • In Stock
The Allen-Bradley 1747-ACN15-A (Series A) is a ControlNet Adapter Module designed for the SLC 500 PLC platform. Allen Bradley 1747-ACN15-A is used to connect remote 1746 I/O chassis to a central processor via a high-speed ControlNet communication network.

Allen Bradley 1747-ACN15-A Specification


Manufacturer: Allen-Bradley

Product Line: SLC 500

Country of Origin: United States

HS / Tariff Code: 8517.62.0050

Module Type: ControlNet Remote I/O Adapter Module

Network Interface: 1 x BNC connector (non-redundant media)

Local Interface: 1 x RJ-45 connector (Network Access Port / NAP)

I/O Capacity: Max 3 I/O chassis / Max 30 I/O slots

Backplane Current: 900 mA maximum @ 5V DC

Node Addressing: Hardware-configured via top rotary switches

Diagnostics: Integrated 7-segment display and status LEDs

Lifecycle Status: End of Life / Discontinued


Allen Bradley 1747-ACN15-A Application


Distributed Remote I/O Networking: 1747-ACN15-A ControlNet Adapter Module coordinates remote data exchange between localized 1746 I/O chassis and centralized master controllers without placing a dedicated CPU in every panel.

Slot 0 System Adapter Deployment: 1747-ACN15-A ControlNet Adapter Module installs directly into the processor slot (Slot 0) of a remote 1746 chassis to convert backplane data into high-speed ControlNet protocol signals.

Multi-Chassis Extension Network: 1747-ACN15-A ControlNet Adapter Module links up to 3 physical 1746 expansion chassis (up to 30 hardware slots total) into a single remote network node drop.

SLC-to-SLC Distributed Architecture: Couples remote hardware assemblies to an SLC 5/04 or 5/05 central system utilizing a 1747-SCNR ControlNet Scanner module.

Cross-Platform Legacy Integration: 1747-ACN15-A ControlNet Adapter Module bridges older 1746 I/O components directly into higher-tier control architectures, including ControlLogix, CompactLogix, and PLC-5 ControlNet scanner networks.

Deterministic Process Plant Synchronization: 1747-ACN15-A ControlNet Adapter Module regulates data-sensitive operations requiring exact, predictable token-passing timing (Scheduled Messaging), such as water treatment skids, packaging lines, and conveyor control.

If you want to more details about Allen Bradley 1747-ACN15-A,please contact me without hesitate.Email:sales@sparecenter.com

Allen Bradley 1747-ACN15-A Features


High-Speed Deterministic Network: Allen Bradley ControlNet Adapter Module communicates at a fixed rate of 5 Mbps on ControlNet, delivering predictable response times via scheduled token-passing messaging.

Slot 0 Placement: Allen Bradley ControlNet Adapter Module mounts directly into the dedicated CPU slot of a remote 1746 chassis to orchestrate the entire rack’s backplane data.

30-Slot Maximum Expansion: Allen Bradley ControlNet Adapter Module powers and manages up to 3 interconnecting 1746 I/O chassis under a single node address.

On-Board Diagnostics: Allen Bradley ControlNet Adapter Module incorporates a built-in 7-segment digital display and front LEDs for immediate status checks and error code parsing.

Hardware Address Selection: Allen Bradley ControlNet Adapter Module utilizes integrated top-facing rotary switches for physical, software-free configuration of the network node number.

Local Programming Access: Allen Bradley ControlNet Adapter Module includes a dedicated Network Access Port (NAP) via an RJ-45 interface for localized diagnostic tools and PC terminal hookups.

Flexible Controller Cross-Compatibility: Allen Bradley 1747-ACN15-A connects 1746 I/O architecture seamlessly into SLC 500, PLC-5, and Logix-class automation systems.


Allen Bradley 1747-ACN15-A FAQ


Q: Can the 1747-ACN15-A module be used as a standalone PLC processor in an SLC 500 chassis?
A: No, the 1747-ACN15-A Allen Bradley is strictly a remote network adapter module and cannot execute user ladder logic programs; it must be installed in Slot 0 of a remote chassis to route I/O data back to a master controller.

Q: Does the 1747-ACN15-A adapter support ControlNet media redundancy?
A: No, the 1747-ACN15-A Allen Bradley features only a single BNC network connector (Channel A) and does not support media redundancy, unlike the dual-port 1747-ACN15 module.

Q: What is the maximum number of 1746 I/O slots that a single 1747-ACN15-A can control?
A: A single 1747-ACN15-A Allen Bradley can manage up to 30 slots across a maximum of 3 interconnected 1746 I/O chassis on one single network node.

Q: How do you configure the network node address for the 1747-ACN15-A module?
A: The network node address for the 1747-ACN15-A Allen Bradley is configured physically via the hardware rotary switches located on the top of the module before installation.

Q: What software tool is required to configure the network scheduling for the 1747-ACN15-A?
A: You must use RSNetWorx for ControlNet software to schedule the network bandwidth and establish the I/O connection parameters for the 1747-ACN15-A Allen Bradley.

Q: What does a flashing red LED or specific error code on the 1747-ACN15-A 7-segment display indicate?
A: A flashing red LED or an active error code on the 1747-ACN15-A Allen Bradley onboard display typically indicates a network configuration mismatch, duplicate node address, or backplane communication fault.

Q: Can the 1747-ACN15-A interface 1746 I/O modules directly with a ControlLogix controller?
A: Yes, the 1747-ACN15-A Allen Bradley acts as a cross-platform bridge, allowing a ControlLogix system equipped with a ControlNet bridge module (e.g., 1756-CNB) to control the legacy 1746 I/O rack.

Q: Is the 1747-ACN15-A still actively manufactured by Rockwell Automation?
A: No, the 1747-ACN15-A Allen Bradley has been officially discontinued by the manufacturer, but you can purchase fully tested and certified replacement units directly from our spare center.


Allen Bradley 1747-ACN15-A Images


Allen Bradley 1747-ACN15-A

1747-ACN15-A ControlNet Adapter Module

1747-ACN15-A

1747-ACN15-A ControlNet Adapter Module

1747-ACN15-A ControlNet Adapter Module

1747-ACN15-A ControlNet Adapter Module

Allen Bradley 1747-ACN15-A

1747-ACN15-A ControlNet Adapter Module

Other Modules



1785-L60B1756-CNBR
1756-CN21756-DNB
1746-IB321756-EN2F
1756-IF161756-EN2TR
1747-BA1756-IT6I2
1771-OBD1756-IV16
1203-GD11756-L55M12
1746-HT1756-L55M13
1746-IB161756-L61S
1746-IH161756-L63
1746-IO81756-L63XT
1746-IV161756-L64
1746-NI81756-L65
1746-NIO4I1756-L71S
1746-OB321756-L72
1746-OW161756-LSC8XIB8I
1747-ACN151756-LSP
1747-L5311756-OB16D
1747-SCNR1756-OF6VI
1756-CNB1756-PA75R

1747-ACN15-A

Email: sales@sparecenter.com


CUSTOMER VOICE

Get the latest price? We will reply as soon as possible (within 12 hours)

Sparecenter sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks. Sparecenter is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.
("[type='submit']")